Adjusting
of the frontal limit switch
1. Move the cylinder to the frontal end position
2. Release
pressure from cylinder
3. Loosen lock nut of the frontal
limit switch
4. Turn the limit switch into the cylinder
up to its stop
5. Turn out the limit switch for half
rotation
6. Tighten lock nut at the limit switch |
 |
 |